EFOY Pro 800
Also available as EFOY Pro 800 Duo with two fuel connectors for even more autonomy
EFOY Pro | 800 | 800 Duo | 2400 | 2400 Duo | 12000 Duo |
---|---|---|---|---|---|
Power output | 45 W | 110 W | 500 W | ||
Power output after (operating hours)1 | 25 W (4,500 h) | 80 W (4,500 h) | 400 W (3,000 h) | ||
Nominal voltage | 12 V DC / 24 V DC | 12 V DC / 24 V DC | 24 V DC / 48 V DC | ||
Charging current | 3.75 A / 1.88 A | 9.17 A / 4.58 A | 20.83 A / 10.42 A | ||
Charging current after (operating hours) | 2.08 A / 1.04 A (4,500 h) | 6.67 A / 3.33 A (4,500 h) | 16.67 A / 8.33 A (3,000 h) | ||
Recommended battery capacity2 | 12 V: 40 to 160 Ah 24 V: 10 to 100 Ah |
12 V: 80 to 350 Ah 24 V: 40 to 175 Ah |
24 V: 200 to 875 Ah 48 V: 100 bis 450 Ah |
||
Weight | 8.0 kg (17.6 lbs) | 8.3 kg (18.3 lbs) | 9.0 kg (19.8 lbs) | 9.3 kg (20.5 lbs) | 32.0 kg (70.6 lbs) |
Warranty3 | 24 months / 4,500 operating hours | 24 months / 4,500 operating hours | 24 months / 3,000 operating hours | ||
Connectable cartridges | M5, M10, MT60 / M28 only with M28 adapter | M5, M10, MT60 / M28 only with M28 adapter | M5, M10, MT60 / M28 only with M28 adapter | ||
Number of connectable cartridges (with DCS1) | 1 (2) | 2 (4) | 1 (2) | 2 (4) | 2 (4) |
Length fuel cartridge connector | 70 cm / 27.6 in | 70 cm / 27.6 in | 73 cm / 28.7 in | ||
Switching threshold for automatic battery charging at 12 V / 24 V / 48 V4 | On: 12.3 V / 24.6 V / — Off: 14.2 V / 28.4 V / — |
On: 12.3 V / 24.6 V / — Off: 14.2 V / 28.4 V / — |
On: — V / 24.4 V / 48.8 V Off: — V / 28.4 V / 57.6 V |
||
Required start-up voltage at 12 V / 24 V / 48 V | 9 V / 18.5 V / — | 9 V / 18.5 V / — | — / 20 V / 36 V | ||
Maximum battery voltage at 12 / 24 V / 48 V |
16 V / 32 V / — | 16 V / 32 V / — | — / 31 V / 62 V | ||
Noise level (at 1m / 7m distance) | 42 dB(A) / 25 dB(A) | 42 dB(A) / 25 dB(A) | 62 dB(A) / 45 dB(A) | ||
Nominal Consumption5 | 0.9 l/kWh | 0.9 l/kWh | 0.9 l/kWh | ||
Quiescent current draw at 12 V | 20 mA | 20 mA | 75 mA (at 24 V) | ||
Operating temperature6 | -20 °C to +50 °C / -4 °F to +122 °F | -20 °C to +50 °C / -4 °F to +122 °F | -20 °C to +50 °C / -4 °F to +122 °F | ||
Start-up temperature | +3 °C to +50 °C / +37.4 °F to +122 °F | +3 °C to +50 °C / +37.4 °F to +122 °F | +3 °C to +50 °C / +37.4 °F to +122 °F | ||
Storing temperature | +1 °C to +50 °C / +34 °F to +122 °F | +1 °C to +50 °C / +34 °F to +122 °F | +1 °C to +50 °C / +34 °F to +122 °F | ||
Altitude7 | Standard: 1,500 m / 4,920 ft (up to 2,000m / 6,561 ft) | Standard: 1,500 m / 4,920 ft (up to 2,000m / 6,561 ft) | up to 4,000 m / 13,123 ft | ||
Dimensions D x W x H | 433 x 188 x 278 mm / 17 x 8 x 11 in | 433 x 188 x 278 mm / 17 x 8 x 11 in | 640 x 441 x 310 mm / 25.2 x 17.3 x 12.2 in (7HE) | ||
International Protection (IP-Class) | IP 21 | IP 21 | IP 20 | ||
Inclination along the roll axis | Permanent: max 35°; temporary (<10 min); max 45° | Permanent: max 35°; temporary (<10 min); max 45° | Permanent: max. 10°; temporary (<10 min): max. 45° | ||
Inclination along the lateral axis | Permanent: max. 20° | Permanent: max. 20° | Permanent: max. 10°; temporary (<10 min): max. 45° | ||
Communication protocols | MODBUS RTU; Clear text protocol (SIO commands) | MODBUS RTU; Clear text protocol (SIO commands) | MODBUS RTU; Clear text protocol (SIO commands) | ||
User-Interface | At the unit or via Operating Panel OP2 with text display | At the unit or via Operating Panel OP2 with text display | At the unit with text display or via external operating panel OP2 | ||
Data-Interface | RS232 RJ-45 plug for accessories (e.g. Interface adapter) | RS232 RJ-45 plug for accessories (e.g. Interface adapter) | RS232 RJ-45 plug 2x RS485 RJ-45 plug I/O terminals (A, B, GND) |
||
Electrical Interface | MNL-plug 4-pins (e.g. Tyco Electronics Universal Mate-N-Lok – Nr. 350779) | MNL-plug 4-pins (e.g. Tyco Electronics Universal Mate-N-Lok – Nr. 350779) | Power: +/- terminals: min. 10 mm² Sense: +/- terminals: min. 2 mm² Ground: Terminal: min. 2 mm² |
1) Nominal power varies by ±10 %, decreases with the operation hours. Specification valid within warranty period.
2) Depends on battery type and application – bigger batteries possible, if additional energy source available (e.g. solar)
3) Regional warranty conditions for EFOY Pro fuel cells apply.
4) Factory Setting – can be modified with Interface Adapter and PC or operating panel OP2.
5) Effective consumption depends on operating conditions.
6) At temperatures above +40 °C / +102 °F the power output can decrease. Charging Lithium (LiFePO4) batteries is not always possible at temperatures below 0 °C. The instructions from the battery manufacturer must be observed.
7) During operation above the recommended altitude the power output can decrease.